Opel Vectra B

since 1995 release

Repair and operation of the car



Vektr's Opel of B
+ 1.1. Governing bodies and control devices
+ 2. Maintenance
+ 3. Engines
+ 4. Heating, ventilation
- 5. Fuel system
   - 5.1. Fuel system of petrol engines
      5.1.1. Introduction
      5.1.2. Technical characteristics
      5.1.3. Air filter and inlet channels
      5.1.4. A control system of temperature of the air given to the engine
      5.1.5. Accelerator cable
      5.1.6. Accelerator pedal
      5.1.7. Fuel
      + 5.1.8. System of injection of fuel
      5.1.9. Removal of pressure in fuel system
      5.1.10. Fuel pump
      5.1.11. Fuel level sensor
      5.1.12. Fuel tank
      5.1.13. Throttle case
      5.1.14. Check of system of injection of fuel
      5.1.15. Elements of single-point system of injection of fuel
      + 5.1.16. Elements of multipoint system of injection of fuel
      5.1.17. Inlet collector
      5.1.18. Final collector
      5.1.19. System of production of exhaust gases
   + 5.2. Fuel systems of the diesel engine
+ 6. Systems of start, ignition
+ 7. Transmission
+ 8. Brake system
+ 9. Running gear
+ 10. Body
+ 11. Electric equipment
+ 12. Main malfunctions


d65d3f49

5.1.18. Final collector

Removal and installation

PERFORMANCE ORDER
SOCH engines of 1,6 l
1. Disconnect the electric socket from the oxygen sensor located on sensor wires. Exempt a sensor electrical wiring from fastening brackets so that the sensor could be removed together with a collector.
2. Remove a reception exhaust pipe.
3. Remove a zabornik of the warmed-up air from a final collector.
4. Take the probe of measurement of level of engine oil and remove high-voltage wires from candles of the 2nd and 3rd cylinders. Unscrew and remove the heat-resistant screen of a final collector.
5. Unscrew nuts and remove a final collector from the engine together with laying.
6. Installation is made in the sequence, the return to removal. At the same time it is necessary to use new laying of a final collector.
Other models
7. Remove a secondary pneumatic valve of system of air supply and a connecting branch pipe.
8. On models of 1,6 l disconnect the electric socket of the sensor of oxygen located on wires, exempt an electrical wiring from fastening brackets so that the sensor could be removed together with a collector.
9. Unscrew bolts of fastening of a reception exhaust pipe to a collector.
10. Unscrew nuts and remove a final collector together with laying.